15
ENGLISH
BUS 2EASY DEVICE INSTALLATION
You can add BUS-2EASY devices to the system at any time, proceeding as follows:
1. Cut off the electrical power to the board.
2. Install and set the
BUS-2EASY accessories according to the instructions of the devices.
3. Connect the
BUS-2EASY devices according to the instructions of Chapter ELECTRICAL CONNECTIONS.
4. Power up the board.
5. Complete the procedure for
BUS-2EASY device entry.
BUS-2EASY DEVICE ENTRY
1. Access BASIC programming and scroll through the functions up until
bu. When
F
is released, the display will show the BUS-2EASY de-
vices status (see the figure).
2. Perform the entry: simultaneously press and hold
+
and
-
for at least 5 sec (during this time, the display will blink).
3. Y will appear as a confirmation of entry completion.
4. Release the
+
and
-
buttons. The status of the BUS-2EASY devices will be displayed.
If no BUS device has ever been entered in the board, the display will read
no
.
Encoder 1:ON = correctly connected and
entered
Encoder 2:
ON = correctly connected and entered
BUS Status: always ON
OPEN photocell:
ON = entered and engaged
Opening photocells:
ON = entered and engaged
Closing photocells:
ON = entered and engaged
Fig. Visualising the BUS-2EASY status in the function bu: each segment of the display shows one type of device.
Opening photocells
and Closing photocells:
ON = entered and engaged
St
AUTOMATED SYSTEM STATUS:
You can exit programming, choosing whether or not to save the configuration you just performed.
1. set the choice:
Y to SAVE and EXIT the programming
no to EXIT the programming WITHOUT SAVING
2. press the button F to confirm; at the end the display returns to visualize the automated system status:
Y
00 = CLOSED
01 = OPEN
02 = Stationary then “OPENS”
03 = Stationary then “CLOSES”
04 = In “PAUSE”
05 = Opening
06 = Closing
07 = FAIL SAFE in progress
08 = checking BUS-2EASY devices in progress
09 = Pre-flash then “OPENS”
10 = Pre-flash then “CLOSES”
11 = Emergency open
12 = Emergency close
HP = Hold position