6
F
F
-
+
F
F
+
+
F
+
+
ENGLISH
PROGRAMMING
Programming is divided in two levels:
BASIC programming
ADVANCED programming
The programming phases are (see Tab.):
1. to access PROGRAMMING (1A or 1B);
2. to show the set values and modify them, if you want. Changing the values is effective immediately, while the final memorisation must be carried out
upon exiting programming (
St).
3. exit the programming by using
St function. Select Y to SAVE the configuration you just performed, otherwise select no to EXIT WITHOUT
SAVING any changes.
You can EXIT programming at anytime:
press and hold F and then also
-
to switch directly to St.
F
+
-
This board also allows programming using a PC or MAC.
This programming requires connection to PC/MAC via USB cable and USB-B relevant port.
The programming SOFTWARE with relevant instructions, must be downloaded from the website
:
www.faacgroup.com
The programming using a PC/MAC, with the default PASSWORD does not inhibit the programming by board. The writing
PC will be displayed
in correspondence with the modified values. Notes: when you modify the values by board the previous PC/MAC programming will be overwrote.
The default password is 0000.
The programming using a PC/MAC, with a modified PASSWORD (different from the default one), will inhibit the programming by board. If one
of the buttons is pressed, the display will show
PC programming for 5 sec and changes will be allowed only by PC /MAC.
쐃쐇쐋
BASIC PROGRAMMING
1A. PRESS AND HOLD F :
THE FIRST FUNCTION APPEARS
Í
1
RELEASE F:
THE FUNCTION VA LU E
IS DISPLAYED
USING
+
OR
-
,
SCROLL THE
AVAI LAB LE VAL UES
UNTIL THE THE
DESIRED ONE
PRESS
F:
TO MOVE TO
THE NEXT
FUNCTION
Í
1
FUNCTION St
(LAST BASIC OR ADVANCED
FUNCTION)
ADVANCED PROGRAMMING
1B. PRESS AND HOLD F AND
THEN ALSO
+
:
THE FIRST FUNCTION APPEARS
Í
1
RELEASE THE KEYS:
THE FUNCTION VA LU E
IS DISPLAYED
SELECT
Y TO SAVE THE
PROGRAMMING
OTHERWISE
SELECT
no TO EXIT THE
PROGRAMMING WITHOUT
SAVING
Í
1
THE FUNCTION IS DISPLAYED UNTIL YOU HOLD
Tab. Programming phases.
Connector J13 – XF MODULE rapid connection
The control unit has an integrated 2-channel decoding system (DS, SLH, LC/RC) named OMNIDEC. This sy-
stem makes it possible to save – through an extra receiver module – XF433 or XF868 radio commands of the
same frequency, but of a different type (DS, SLH, LC/RC). It is possible to save both total opening (OPEN A)
and partial opening (OPEN B) of the automated system, up to a maximum of 256 channels.
Insert and remove the boards only after cutting power.