N° ERROR SOLUTION
01
Board broken Replace the board
02
Thermal protection active Wait for the board to cool down, check for overloads
03
Motor 1 faulty
Check that the motor works and that the wiring is not interrupted or damaged
04
Motor 2 faulty
05
Invalid SETUP Repeat board SETUP
08
BUS-2EASY device error Ensure that no two pairs of devices have the same address.
09
BUS-2EASY output
short-circuit
Check the connections of the connected and entered
BUS-2EASY devices
10
Motor 1 limit switch error Check the limit switch connections for motor 1
11
Motor 2 limit switch error Check the limit switch connections for motor 2
12
BUS-2EASY call Ensure that the BUS devices are operating correctly and, if necessary, repeat BUS device acquisition
13
FAIL SAFE Check that the safety devices (photocells) are operating correctly
14
Configuration error Check that the board is configured correctly (basic and advanced programming) and, if necessary, repeat SETUP
15
Movement timeout reached
Check that the motors are blocked; check that any limit switches are activated correctly and that the mechanical stops
are present.
16
Deep sleep The board is in advanced energy-saving mode. No action required.
17
Motor 1 encoder fault Check the connections or replace motor 1 encoder
18
Motor 2 encoder fault Check the connections or replace motor 2 encoder
19
Incorrect memory data Repeat BUS-2EASY device entry and/or re-program the board
45
Battery operation No action required.
93
High absorption at +24V Check that absorption by the accessories connected is within permitted limits
N° ALARM Solution/Description
20
Obstacle on MOTOR 1 (only with en-
coder)
Remove any possible obstacle on leaf 1
21
Obstacle on MOTOR 2 (only with en-
coder)
Remove any possible obstacle on leaf 2
22
MOTOR 1 current limited Check the force set on motor 1
23
MOTOR 2 current limited Check the force set on motor 2
25
LOCK 1 output short-circuit Remove the cause of the short-circuit
26
LOCK 2 output short-circuit Remove the cause of the short-circuit
27
Nr. of consecutive obstacles exceeded
during opening
Remove any possible obstacle.
Should the problem persist, repeat SETUP
28
Nr. of consecutive obstacles exceeded
during closing
Remove any possible obstacle.
Should the problem persist, repeat SETUP
30
XF radio code memory full
Cancel the radio codes that are not being used using the PC program or use an additional DEC/MINIDEC/
RP module
31
Tampering alarm
Movement was performed with automation in status
St
=
00
or
01
. Perform a manoeuvre cycle.
32
Emergency active Check that the emergency input is not active (configuration only possible from PC/Mac)
35
TIMER active and TIMER function operating: TIMER function is operating
40
Service request Contact the installer for maintenance
50
The HOLD POSITION is operating (active
on PC/MAC )
HOLD POSITION function is operating
60
TIMER active and error in TIMER data Reload a correct TIMER configuration with the PC/MAC programme
62
Loss of time and date on the board (only
if the TIMER is operating)
Reload the time and date with the PC/MAC programme and replace the BAT1 - CR2032 buffer battery
63
JOLLY TIMER is activated JOLLY TIMER is enabled by terminal board J3