EasyManua.ls Logo

FAAC E124 - EU Declaration of Conformity; Introduction to the Instruction Manual

FAAC E124
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
115 V ~ 230 V ~
ENGLISH
LED OPERATION
POWER FEED
LED
Description
ON
(contact closed)
OFF
(contact open)
DL1
IN1
OPEN A
Command enabled
Command disabled
DL2
IN2
OPEN B
Command enabled
Command disabled
DL3
IN3
STOP
Command
disabled
Command enabled
DL4
IN4
FSW OP
Safety devices
disabled
Safety devices tripped
DL5
IN5 -
FSW CL
Safety devices
disabled
Safety devices tripped
DL6
FCA1
Opening travel-limit
devices free
Opening travel-limit
devices engaged
DL7
FCC1
Closing travel-limit
devices free
Closing travel-limit
devices engaged
DL8
FCA2
Opening travel-limit
devices free
Opening travel-limit
devices engaged
DL9
FCC2
Closing travel-limit
devices free
Closing travel-limit
devices engaged
DL10
ENC1
Flashing during operation
(Gatecoder)
DL11
ENC2
Flashing during operation
(Gatecoder)
DL12 SIGNALLING LED FOR DEVICE BUS-2EASY ACTIVE
DL13 SIGNALLING LED FOR BUS 2-EASY DIAGNOSTICS
DL14
LED SIGNALLING PRIMARY POWER ON
DL15 LED SIGNALLING SECONDARY POWER ON
DL16
LED FOR “SW1” PUSH-BUTTON (R1 PUSH-BUTTON)
DL17
LED FOR “SW2” PUSH-BUTTON (R2 PUSH-BUTTON)
DL18
LED FOR “SW3” PUSH-BUTTON (SETUP PUSH-BUTTON)
DL19 LED “RESET SW” PUSH-BUTTON
DL20 ALARM SIGNALLING LED “ALARM
INPUTS DEFAULT SETTING
Terminal-board J4
IN1 OPEN A N.O. contact
IN2 OPEN B N.O. contact
IN3 STOP N.C. contact
IN4 FSW OP N.C. contact
IN5 FSW CL N.C. contact
J1: Select the correct power feed, by turning the power switching
selector to its correct position (Default 230 V
~)
To ensure correct operation, the switching feeder must
be connected to the earth conductor in the system. Install
an adequate differential thermal breaker upstream of the
system.
SECONDARY POWER FEED
J2: In the absence of a primary feed from the mains, the control unit can
be fed by a secondary low voltage (24V
) power feed. Power can
be supplied by a pack of batteries, recharged by a battery charger
integrated in the board, or by a stabilised power feeder. In both
cases, the power supply must have the following characteristics:
If you use an external stabilised feeder, you must disable
the “battery charger” function via the PC (see dedicated
instructions).
Voltage: (24 ± 4) V
Current: 16 A max.
Connector J13 – XF Module (OMNIDEC)
Channel 1 OPEN A
Channel 2 OPEN B
Connector J14 - Radio
Channel 1 RP OPEN A
Channel 2 RP2 OPEN B
TERMINAL BOARD MOTORS
J11 (MOT1): Connection of motor connected to leaf 1, i.e. the leaf
ZKLFKRSHQV¿UVWGXULQJDQRSHQLQJRSHUDWLRQ
J12 (MOT2): Connection of the motor connected to leaf 2, i.e. the leaf
which opens second.
If only one motor is connected, it must be connected to
terminal J11 (MOT1).
,IGXULQJWKH¿UVWPRYHPHQWRIWKH6(783SURFHGXUH
the leaves open instead of closing, the motor connection
cables must be changed over.
Flashing LED ALARM indicates alarm in progress (a
situation which does not prejudice gate operation)
LED ALARM on steady light indicates error in progress
(a situation which blocks operation until cause of error
is eliminated)

Other manuals for FAAC E124

Related product manuals