E124 17 532365 - Rev.A
Translation of the original instructions
ENGLISH
En
ENCODER Enables/disables the encoder on both motors. no disa-
bled,
Y enabled (* = non modifiable)
no no no Y
*
no Y
*
Y
*
Y
*
FA
OPENING LIMIT SWITCH Enables/disables the opening limit switches, to
stop the automation or start the slowdown. Modifying the value requires
a new SETUP.
no disabled, 01 to stop, 02 to start slowdown
no
FC
CLOSING LIMIT SWITCH Enables/disables the closing limit switches, to
stop the automation or start the slowdown. Modifying the value requires
a new SETUP.
no disabled, 01 to stop, 02 to start slowdown
no
Cd
CLOSING DELAY NOT displayed if Mn = 1. The delay is applied to Leaf 1.
00… 59 s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds (separated
by a point), up to a maximum of
1.3 minutes.
1.0…1.3 Adjustment step: 10 s
E.g.
1.2 = 1 min and 20 s.
05
bu
BUS 2easyREGISTRATION See the § specific section.
no
M2
MOTOR 2 OPERATION NOT displayed if Mn = 1. In this function, buttons
+ and - operate Motor 2 in hold-to-run mode.
++ OPEN (displaying oP),
--
CLOSE (displaying cL)
--
M1
MOTOR 1 OPERATION In this function, buttons + and - operate Motor 1
in hold-to-run mode.
++ OPEN (displaying oP),
--
CLOSE (displaying cL)
--
tL
SETUP See the § specific section.
--
St
LEAVING THE PROGRAMMING MODE
Y Exit saving the settings
no Exit without saving the programming
After having confirmed using button
FF, the display indicates the STATUS of
the automation:
Y
00 CLOSED
01 OPEN
02 STATIONARY THEN
OPENS
03 STATIONARY THEN
CLOSES
04 in PAUSE
05 OPENING
06 CLOSING
07 FAIL- SAFE in progress
08 VERIFYING BUS 2easy
09 PRE-FLASHING and then
OPENS
10 PRE-FLASHING and then
CLOSES
11 EMERGENCY OPEN
12 EMERGENCY CLOSE
HP Hold Position
. (point flashing) SLEEP