21
E124 31 532365 - Rev.A
RADIO
CLOCK BATTERY
PRGRM
USB
XF MODULE
+
8.8.
1 2 1 2 1 23 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20
DL1
DL2 DL3 DL4 DL9 DL10 DL11DL12
SW3
DL14
BATTERY
SW1
SW2
DL13 DL5 DL6 DL7 DL8
ALARM
RESET
DL12 DL1 DL2 DL3 DL4 DL6 DL7 DL8 DL9DL5DL13 DL10 DL11
2EASY OUT2 OUT1
LAMP
LOCK MOT1 MOT2
+
-
+
-
IN1
IN2
IN4
IN5
GND
IN3
GND
+24
FCA1
FCC1
FCC2
FCA2
GND
GND
GND
ENC1
+24
ENC2
Simply Connect
XMB GSM Mobile, Bluetooth Low Energy
XWBL WiFi, LAN ethernet, Bluetooth Low Energy
Translation of the original instructions
ENGLISH
7.8 SIMPLY CONNECT
!
To safeguard people and property, the automation must
be supervised and there must be not be any unauthorised
persons present for the entire duration of operations
carried out remotely (SETUP and/or modifications to
operating parameters).
L
Simply Connect requires E124 firmware version FW
4.0 or later.
When programming is taking place via Simply Connect,
programming via the board is inhibited.
1. Insert the module into the dedicated plug con-
nectors.
2. With the board powered, check the signalling LEDs
(see module instructions).
3. Enable communication by assigning a channel
(CH) to the board.
Basic programming, function
C
C:
-
1 CH 1, 2 CH 2, 3 CH 3, 4 CH 4
IMPORTANT if the automation is in a Multicom network,
assign a different channel compared to the other
boards that are connected.
4. Install the Simply Connect installer App (supplied