2 Basic programming menu
Basic function DEFAULT:
0 1 2 3 4 5 6 7
C
C
Simply Connect To enable Simply Connect, select a communication
channel (CH 1…4).
0 disabled, 1 (CH 1), 2 (CH 2), 3 (CH 3), 4 (CH 4)
0
cF
TYPE OF AUTOMATION Select the type of actuator installed (board loads
the relative default configuration).
0
The DEFAULT settings for the type of automation
are indicated in the corresponding column (e.g.
column
4 for S418).
The letters
EP indicate a "mixed" automa-
tion: 2 leaves with 2 different actuators (from
Simply Connect).
0 no FAAC actuator
1 412, 413, 415, 770, 390, 770N
2 391
3 S700H/S800H
4 S418
5 S450H
6 S800H ENC
7 S2500 I
dF
DEFAULT CONFIGURATION Y indicates if the programming corresponds
to the default settings. Select
Y if you wish to reload the default values for
the type of automation.
Y the programming corresponds to the DEFAULT settings
no the programming does not correspond to the DEFAULT settings
Y
LO
OPERATING LOGICS
E
E Semi-automatic
EP Semi-automatic step by step
S Automatic Safety
SA Automatic Safety 2
SP Automatic step by step
A1 Automatic 1
A Automatic
AP Automatic step by step
At Automatic with timer function
b Semi-automatic b
bC Mixed (Impulse opening / Hold-
to-run closing)
C Hold-to-run
CU Displayed if there is a CUSTOM
logic from Simply Connect.
PA
PAUSE TIME A Displayed only in logics with automatic closing. This
function specifies the pause time if the automation has been opened by the
OPEN A command.
00… 59 s Adjustment step: 1 s
The display subsequently changes to minutes and tens of seconds (separated
by a point) and the time is adjusted in 10 s steps, up to the maximum value
of
9.5 minutes.
E.g.
1.2 = 1 min and 20 s
30
Pb
PAUSE TIME B Displayed only in logics with automatic closing. This func-
tion specifies the pause time if the automation has been opened by the OPEN B
command (adjustment similar to
PA)
30
Mn
NUMBER of MOTORS enabled.
1 1 motor, 2 2 motors
2
F1
MOTOR 1 POWER
01…50 (levels)
25 25 25 40 25 35 40 15
F2
MOTOR 2 POWER NOT displayed if Mn = 1.
01…50 (levels)
25 25 25 40 25 35 40 15
SP
SPEED Speed of movement.
01… 10 (levels)
08