Page | 4
The E145S Control Board allows for the use of traditional photocells (n/c with relay). Below is a layout drawing showing the
basic positions normally covered. The wiring diagram is for Fail-Safe enabled photocells. In order to comply with the standards,
all devices used for safety should either have a circuit monitored by the control board or be self-monitoring. FAAC Control
boards are able to perform the monitoring by the use of a Fail-Safe function, whereby the test negative is momentarily dropped
(please note that this may not be compatible with non-FAAC equipment). This function is enabled by entering Advanced
Programming (detailed below) and setting function o1 to 01.
Electrical Connectio
ns
Connection of Traditional Photocells