7
ENGLISH
ADVANCED PROGRAMMING
Display Function dF01
Po
POSITION OF DOOR:
Shows the position of the door during motorised movement from 00 to 59.
For an explanation of parameter PO
refer to chapter 7.5.
00
P1
UPPER LIMIT OF ZONE A:
Defines the upper limit of zone A, in which to subsequently adjust the force, speed and sensitivity functions of
the encoder F1, S
1
, E1. (input value P1 as explained in chapter 7.5).
20
P2
UPPER LIMIT OF ZONE B:
Defines the upper limit of zone B, in which to subsequently adjust the force, speed and sensitivity functions of
the encoder F2, S2, E2. (input value P2 as explained in chapter 7.5).
32
oF
OPENING FORCE:
Adjusts force during opening from 01 to 50.
25
F2
CLOSING FORCE IN ZONE B:
Adjusts force during closing from 01 to 50.
30
F1
CLOSING FORCE IN ZONE A:
Adjusts force during closing from 01 to 50.
20
S2
CLOSING SPEED IN ZONE B:
Adjusts closing speed in zone B from 01 to 10
(10 = max. speed, 01 = min. speed).
05
S1
CLOSING SPEED IN ZONE A:
Adjusts closing speed in zone A from 01 to 10
(10 = max. speed, 01 = min. speed).
03
E2
ENCODER SENSITIVITY IN ZONE B:
Adjusts anti-crushing sensitivity in zone B from 01 to 50
(50 = min. sensitivity, 01 = max. sensitivity).
04
E1
ENCODER SENSITIVITY IN ZONE A:
Adjusts anti-crushing sensitivity in zone A from 01 to 50
(50 = min. sensitivity, 01 = max. sensitivity).
03
LP
COURTESY LIGHT:
To set lighted time of the courtesy light.
Can be adjusted from 0 to 59 sec in one-second steps.
Afterwards, the viewing changes in minutes and tenths of a second (separated by a dot) and time is adjusted
in 10 second steps, up to the maximum value of 4.1 minutes.
E.g. if the display shows 2.5, the pause time will be 2 min and 50 sec.
30
Tab. 3