E844 3PH 12 532315 - Rev.B
Translation of the original instructions
ENGLISH
Function default
dF
Type of gearmotor
00 844 R 3PH (400 V~ 3PH)
01 884 MC 3PH (400 V~ 3PH / 230 V~ 3PH)
02 844 R 3PH (230 V~ 3PH)
00
Lo
Operating logic
E Semi-automatic
EP Semi-automatic step by step
A Automatic
AP Automatic step by step
S Automatic Safety
b Semi-automatic B
C Hold-to-run
EP
PA
Pause time
carried out in the automatic logics
From 0 s to 9.5 min ; adjustment in steps of 1
s from 0 to 59, then in steps of 10 s
30
Pb
Partial pause time
carried out in the automatic logics following
a partial opening
From 0 s to 9.5 min ; adjustment in steps of 1
s from 0 to 59, then in steps of 10 s
30
FS
Failsafe
no disabled
01 enabled only on SAFE OP
02 enabled only on SAFE CL
03 enabled on SAFE OP and SAFE CL
no
EC
Encoder obstacle detection sensitivity
(available only for board installed on
844 R 3PH )
00 Obstacle detection not enabled
01 (maximum sensitivity) ... 99 (mini-
mum sensitivity)
00
SS
SOFT-START
acceleration ramp at each start
(available only for 844 R 3PH )
Y enabled
no not enabled
Y
rP
Pre-limit switch deceleration
as a percentage of the travel of the gate that
was memorised during learning procedure for
the work times
(available only for 844 R 3PH)
00
no slowdown
05...30 %
00
PO
Partial opening width
01...20 in steps of 1 s
05
Function default
o1
Output OUT1 configuration
the output is activated according to selected
function
00
00 Always active
02 Indicator Light (on during opening and
when open/in pause, off when closed,
flashing during closing)
03 Courtesy Light
04 Error
05 Status OPEN/IN PAUSE
06 Status CLOSED
07 Status MOVING
08 Status EMERGENCY
09 Status OPENING
10 Status CLOSING
12 Safety device active
13 TRAFFIC LIGHT CONTROL (active when
opening/in pause/open)
t1
OUT1 timing
only for the Courtesy Light
00...99 min
02
o2
Output OUT2 configuration
the output is activated according to selected
function
00
00 Always active
02 LED
03 Courtesy Light
04 Error
05 Status OPEN/IN PAUSE
06 Status CLOSED
07 Status MOVING
08 Status EMERGENCY
09 Status OPENING
10 Status CLOSING
12 Safety device active
13 TRAFFIC LIGHT CONTROL (active when
opening/in pause/open)
t2
OUT2 timing
only for the Courtesy Light
00...99 min
02
nc
Cycle counter (x1000)
00...99 in steps of 1000
00