Intrusion or sabotage alarm
If a detector is tripped in one of the protected areas:
- the sensor sends a signal to the control unit,
- If the detector is set for a delayed alarm, the control
unit sounds a warning BEEP for 45 seconds.
- then the control unit siren is tripped and the telephone
transmitter calls the recorded numbers.
Sabotage alarm: if one of the system enclosures is
open, the siren and the telephone transmitter are
immediately tripped.
Absence of a device (supervision)
or discharged batteries
- the siren and the telephone transmitter are not
enabled,
- the problem is signalled, when the alarm is enabled or
disabled, by some beeps and on the control keypad.
Technical alarm (optional) or
emergency call (emergency call
panic button)
- the telephone transmitter is enabled and the control
unit siren emits a series of beeps,
- the outdoor siren is not enabled.
Siren enab
Siren enab
lement c
lement c
yc
yc
le
le
In case of an alarm the siren sounds for 90 seconds.
If the alarm continues, the siren will sound again 3
times for 90 seconds.
To stop an alarm in progress, press the OFF Key of a
remote-control or keypad.
Use