Technical specifications
Main
enclosure
Magnet
enclosure
A
B
Wood support
D1
D2
D3
A
B
16 mm
12 mm
14 mm
16 mm
9 mm
6 mm
8 mm
9 mm
16 mm
11 mm
15 mm
15 mm
9 mm
6.5 mm
8 mm
8 mm
D1
D2
D3
A = movement in upper right
B = movement in lower left
Metal Support
ClosedClosed
OpenOpen
D1-D2-D3 are the 3 movement
directions of the magnet/detector
Distance for insertion of
opening detector
Siren transmission control unit
Power supply: four 1.5 volt alkaline batteries type LR20 (included)..
Time range: 2.5 years under normal use conditions.
Functions: double band system, 102 dB integrated siren, historic
record of 200 events and 40 ON/OFF, radio learning, radio codes
> 16 million.
Max installation: 40 detectors, 14 remote-controls and keypads,
4 control keypads, 4 sirens, 2 telephone transmitters, 4 emergency
call panic buttons.
Self-protection: at opening.
Frequency: 434 and 868 MHz band.
Radio range: In free field: from 200 to 300 m,
Indoors: according to environment.
Consumption on stand-by: ~320 µA (max. 350 µA).
Average consumption in alarm state: <= 300 mA.
Average consumption in transmission status: <= 50 mA.
Enclosure: ABS-PC.
Dimensions: 284 X 190 X 80 mm.
Operating temperature: +5° C / + 55 °C.
Weight (including batteries): 1 kg.
Connection to telephone network.
Maximum number of main (RTCP) lines: 1.
Connection method: - non-removable RJ11 integrated socket.
- or terminal-board, detachable in 5 points.
Protocol: FSK 200 baud and ID contact.
Selective telephone calls.
max four 14-digit saved numbers.
Configuration, events historic record and parameters consultation
by telephone call.
Opening detector
Power supply: two 1.5 volt alkaline batteries type LR203 (or AAA).
Time range: 3 years under normal use conditions.
Radio range: from 200 to 300 m according to environment.
Radio frequency: band 434 and 868 MHz, class I.
Self-protection: at opening.
Use: only indoors
Consumption on stand-by: ~ 10 µA.
Average consumption in transmission status: 15 mA maximum
Protection index: IP30-IK02.
Operating temperature: + 5° C / +55° C.
Dimensions: 102 x 35.5 x 31 mm
Weight (including batteries): 100 gr.
Movement detector
Power supply: two 1.5 volt alkaline batteries type LR6 (or AA).
Time range: 3 years under normal use conditions.
Optical range: 12 m.
Opening angle: 90° horizontal.
Radio frequency: band 434 and 868 MHz.
Consumption in stand-by: ~ 50 µA.
Use: only indoors
Self-protection: at opening.
Dimensions: 110 x 90 x 58 mm
Operating temperature: + 5° C / +55° C.
Enclosure: ABS-PC.
Weight (including batteries): 170 gr.
Remote-control
Power supply: two 3 V lithium batteries CR2032.
Time range: 4-5 years
Radio frequency: 868MHz.
Troubleshooting
Control keypad
Power supply: four 1.5 volt alkaline batteries type LR6 (or AA).
Time range: 3 years under normal use conditions.
Radio range: In free field: from 200 to 300 m.
Indoors: according to environment
Radio frequency: 868 Mhz two-way
Consumption on stand-by: ~ 30 µA.
Average consumption in transmission status: <= 50 mA.
Number of codes: 1 main and 2 secondary.
Self-protection: on opening and detachment.
Anti-fraud: keypad locked.
Functions: mode ON / mode OFF / Areas from 1 to 4.
200 historic record events,
40 historic record alarm ON/OFF,
Facility for naming devices (list of standard words and
user),
Radio learning,
Radio coding > 16 million codes.
Dimensions: 145 x 77.5 x 33 mm.
Operating temperature: + 5° C / +40° C.
Enclosure: ABS-PC.
Weight (including batteries): 160 gr.