Installation
312
8.
INSTALLATION
Connection between modules
284
DDS
HARDWARE
Ref.1310
Electrical configurations of the resistor with compact drives
F. H8/13
Electrical configurations of the Ballast resistor with compact drives.
C
ONTROL
L-
L+
R.int
R.ext
ACD/SCD/CMC
1.15
L+
ReRi
R.int
ER+TH-X/X
L+
ReRi
C
ONTROL
L-
L+
L- L-
ACD/SCD/CMC
X.XX
ER+TH-18/X+FAN
Configuration
for connecting the
internal
Ballast resistor
Configuration
for connecting the
external
Ballast resistor
WARNING. Never connect an external resistor in parallel with the internal
Ballast resistor. Ignoring this warning may cause severe damage to the
system.