SECTION 10 -- ENGINE -- CHAPTER 1
91
6. Remove the two retaining bolts (3) and the cen-
tral tappet inspection cover (2) together with the
engine vapor intake pipe (1) and the cover base
seal.
195
7. Remove the retaining bolt and the rear tappet in-
spection cover (1) together with the cover base
seal.
196
8. After taking off the covers, adjust the clearance
between the rocker arms and valves using an Al-
len wrench (1), box wrench (2) and feeler gauge
(3).
The working clearance should be:
-- inlet valves =0.30± 0.05 mm
(0.0118 ± 0.019 in)
-- exhaust valves =0.55± 0.05 mm
(0.0216 ± 0.0019 in).
MIF1016A
197