00020EN Rev.09 – 12/2012 (ORIGINAL INSTRUCTIONS)
Commercial office:
Via Merendi, 22
20010 Cornaredo (MI)
Tel. +39.02.93.991.92
Fax. +39.02.93.991.608
E-mail: info@faster.dgroup.it
OPERATING &
MAINTENANCE MANUAL
FlowFAST H

Questions and Answers

  • S
    Shannon HawkinsAug 4, 2025
    What to do if my Faster FlowFAST H Protection Device cabinet does not work?
    • W
      William MaloneAug 4, 2025
      If your Faster Protection Device cabinet isn't working, there could be a few reasons. First, check the voltage input to the cabinet to ensure the electricity supply hasn't been cut off at the mains. If the electricity supply is ok, the electronic board might be out of order, in that case replace the PCB. Finally, check the fuses and replace them if they are blown.
  • J
    Jason DavisAug 9, 2025
    What to do if Faster FlowFAST H Protection Device shows a “Black-out ” Alarm?
    • T
      troy18Aug 9, 2025
      If your Faster Protection Device displays a “Black-out ” Alarm, which indicates a probable exchange of air between the work chamber and the outside (and possible contamination of the environment), check the feeding cable, the connection plug/socket, and the power supply line. You can also press the “ESC” key to silence the alarm.
  • T
    tara95Aug 14, 2025
    What to do if my Faster FlowFAST H Protection Device displays a “minimum LAF alarm”?
    • T
      Teresa LopezAug 14, 2025
      If your Faster Protection Device displays a “minimum LAF alarm”, which indicates possible contamination of the product, the HEPA filters might be clogged, so replace them. Alternatively, the main motor-fan might not be working; in that case, check the terminal voltage of the power card of the main motor-fan. You may also need to check the F7 fuse on the power card, replace the power card, or replace the microprocessor card.
  • J
    Jennifer BenjaminAug 19, 2025
    How to fix “HEPA filters check” alarm on Faster Protection Device?
    • T
      teresarodriguezAug 20, 2025
      If your Faster Protection Device displays a “HEPA filters check” alarm, it means that the main HEPA filter is clogged. Replace the HEPA filter to resolve this issue.
  • S
    sarahmillerAug 25, 2025
    What to do if my Faster FlowFAST H shows Alarm “Sensors failure”?
    • J
      Joy WoodAug 25, 2025
      If your Faster Protection Device displays an “Sensors failure” Alarm, it means that there is a failure of sensor XX. Replace the XX sensor.
  • S
    Stacy KingAug 29, 2025
    Why does my Faster FlowFAST H show Alarm: “No encoder input LAF”?
    • S
      Shelby KnappAug 29, 2025
      If your Faster Protection Device displays an “No encoder input LAF” Alarm, it means there's no signal from the LAF flow sensor. To fix this, replace the LAF sensor.

Summary

1 General Information

2 Installation

2.A Delivery Checks and Instructions

Guidelines for inspecting the cabinet upon arrival to identify any transport damage.

2.B Installation Requirements

Specifies environmental conditions and placement needs for optimal cabinet performance.

2.C Electrical and Gas Connections

Details on connecting the cabinet to electrical power and gas/vacuum networks.

3 Operation Principles

4 Operation

4.A Scope of Use

Defines the intended use and international standards met by the cabinet.

4.B Control and Regulation Systems

Describes the systems used to maintain constant airflow velocity, including manual and automatic options.

4.C Control Board Symbols

Lists and describes all symbols and controls present on the cabinet's control panel.

4.D Operator Menu (Optional)

Details on accessing and navigating the optional operator menu for settings and configurations.

4.E Waste Disposal Information

Information on the correct disposal of electric and electronic devices and contaminated materials.

5 Limitations and Precautions

Precautions for Correct Cabinet Use

Crucial precautions, including handling pathogenic materials and avoiding corrosive substances.

6 Operating Procedures

6.A Preliminary Checks

Essential checks to perform before operating the cabinet to ensure readiness and safety.

6.B Switching On the Cabinet

Detailed procedure for powering on the cabinet and preparing it for use.

6.C Switching Off the Cabinet

Instructions for safely shutting down the cabinet at the end of a work session.

7 Maintenance

7.A Daily Cleaning Instructions

Daily cleaning procedures for the cabinet's exterior and interior surfaces.

7.B Prefilter Cleaning

Instructions for users on how to clean the pre-filters monthly.

7.C HEPA Filter Replacement

Procedure for replacing the HEPA filter, to be performed by qualified technical personnel.

7.D Motor-Fan Replacement

Instructions for technical personnel to replace the motor-fan unit.

7.E Fluorescent Lamp Replacement

User-level instructions for replacing the fluorescent lighting lamps.

7.F UV Germicidal Lamp Replacement (Optional)

User-level instructions for replacing the optional UV germicidal lamp.

7.G List of Spare Parts

A comprehensive list of available spare parts for the FlowFAST H cabinet.

8 Troubleshooting

9 Technical Specifications

10 Assembling and Disassembling Instructions

11 Transport, Packing, and Storage

12 Additional Information

12.A Guarantee

Details the warranty period and conditions for the FlowFAST H cabinet.

12.B Technical Assistance Address

Information on how to contact technical assistance or distributors for support.

13 Maintenance Operations Diagram

14 Diagrams: Front and Side Views

14.A Front Diagram

Frontal view of the cabinet showing useful and overall dimensions.

14.B Side Diagram

Side view of the cabinet with detailed dimensions and component labels.

15 Cabinet Mounting

16 Support Table Assembly

17 Cabinet Mounting on Table (Optional)

18 Side Diagram with UV Lamp (Optional)

19 Sensors List

20 Wiring Diagram

21 Declaration of Conformity

Faster FlowFAST H Specifications

General IconGeneral
BrandFaster
ModelFlowFAST H
CategoryProtection Device
LanguageEnglish