FCI WATERMAKERS, INC. 93Operational Instructions
FLUSH SEQUENCE
At any point when the system is running, the stop button can be pressed. When
pressed, the Quality Valve will divert overboard. If equipped with APC, the High
Pressure Control Valve with go to its open position. e HPP will turn o. e
LPP will turn o. ere will be a 10 seconds delay prior to starting the ush.
When the system is in Flush Sequence and the Delay Timer is counting down:
LPP – is o
HPP – is o
FWF Valve – is closed
Quality Valve – directed overboard
APC (if equipped) – open position
Once the delay timer has expired, the Flush Sequence will start. e Fresh Water Flush
valve will open and will remain open until the Fresh Water Flush Timer expires. Once
completed the system will return to the Home Screen and be in Standby Mode.
When the system is in Flush Sequence and Fresh Water Flush Timer is counting down;
LPP – is o
HPP – is o
FWF Valve – is open
Quality Valve – directed overboard
APC (if equipped) – open position
SYSTEM FUNCTIONALITY (continued)