FCI WATERMAKERS, INC. 97
5. Over Production Shutdown:
Cause: Triggered when the Over Production Alarm has been active for 60
seconds, or when the Product Flow is 20% greater than the rated output.
Clear: Select the alarm, press the Ack Selected button, and clear
the system by pressing icon in the lower le hand corner.
6. High Pressure Shutdown:
Cause: Triggered when the system’s pressure reaches 1000 psi.
Clear: Select the alarm, press the Ack Selected button, and clear
the system by pressing icon in the lower le hand corner.
7. High TDS Shutdown:
Cause: Triggered when the High TDS Alarm has been active
for set High TDS Shutdown Timer duration.
Clear: Select the alarm, press the Ack Selected button, and clear
the system by pressing icon in the lower le hand corner.
SYSTEM ALARMS (continued)