EasyManua.ls Logo

Feig Electronic TST WUI - 6 Other Connection Possibilities; Photo Eye and External Controls; 7 Inputs Overview; Input Terminal Descriptions

Feig Electronic TST WUI
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TST Startup WUI
FEIG ELECTRONIC GmbH Page 12 of 20 WUI_Inbetriebnahme2_GB.doc
6 Other connection possibilities
6.1 Photo eye
+24V
GND
71
X25
6564
66
72
74
73
7675
Figure 10: Photo eye connection
6.2 External control device
+24V
OPEN
STOP
CLOSE
CLOSE
OPEN
STOP
X23
5251 5453
X24
61
Figure 11: External control device
7 Inputs overview
E-Stop ext. 21
E-Stop ext. 22
GND
GND
GND
+12V
Arm broken / Crash
GND
Dead man / Auto
+24V
GND
GND
41
X22
42 44
43 45
X23
5251 5453 62
X24
61 63 71
X25
6564
66
72 7473 7675
X26
81
83
82 8584 86
Si-Lei
GND
GND
+24V
Limit OPEN
Limit CLOSE
+24V
Photo eye
Pull switch OSCS
+24V
Arm blocked
+24V
E-Stop ext. 11
E-Stop ext. 12
23 45 678910
Door switch
Thermopill
Open Ext. 1
Pull switch EO
Close Ext.
1
343231 33
X20
35
36

Related product manuals