TST Startup WUI
FEIG ELECTRONIC GmbH Page 19 of 20 WUI_Inbetriebnahme2_GB.doc
11.2 Information messages
General messages
STOP
Stop / Reset state, wait for next incoming command
_Eu_ End position Lower Eu
Eu
End position Lower locked no raising possible (e.g., lock-door)
ZUF@
Closing active
-
Eo
- End position Upper Eo
Eo
End position Upper locked no closing possible (e.g., safety edge)
@AUF
Opening active
-E1- End position middle E1 (intermediate stop position)
E1
End position middle locked no closing possible (e.g., safety edge)
FAIL
Fault only deadman travel is possible, possibly automatic opening
NA
E-Stop No travel possible, hardware safety chain interrupted
NOTF
E-travel Deadman travel without taking into account safeties, etc.
'Hd'
Manual Deadman mode
ParA Parameterizing
'Au'
Automatic indicates change from „Manual“ to „Automatic“ status
'Hc'
Semi-automatic indicates change from „Manual“ to „Semi-automatic“
WU
Initial display after power up (Power Up and self-test)
Status messages during deadman
Hd.cL
Deadman close (membrane key: CLOSE)
Hd.oP
Deadman open (membrane key: OPEN)
Hd.Eu
End position Lower reached, no further deadman close possible
Hd.Eo
End position Upper reached, no further deadman open possible
Hd.Ao
Outside of permitted Eo position (no deadman open possible)
Information messages during Automatic mode
I.080
Maintenance required soon / service counter nearly expired
I.100
Speed by reaching the upper limit switch is to high
I.150
Speed by reaching the lower limit switch is to high
I.160
Continuous CLOSED still active
I.170
Forced opening being performed
I.180
Waiting for Foil key pad command
I.185
Reset necessary (P.408)
I.199
Door cycle not plausible (re-initialize Æ Parameters)
I.310
Open-command on Door2 being issued
Information messages while parameterizing
noEr
Error memory: no error saved
Er--
Error memory: if error but no associated message found
Prog
Programming message while carrying out original parameter or default set
General inputs
E.000
OPEN key on membrane keypad
E.050
STOP key on membrane keypad
E.090
CLOSE key on membrane keypad
E.101
Input 1
E.102
Input 2
E.103
Input 3
E.104
Input 4
E.105
Input 5
E.106
Input 6
E.107
Input 7
E.108
Input 8
E.109
Input 9
E.110
Input 10
Safety/Emergency stop chain