Internal system faults
F.935
Stack error
• UserSTack or SystemStack overflowed
• Possible software error due to recursive invocations (e.g.
profile)
F.960
Wrong parameter checksum
• New EPROM version with different parameters
• Controller not yet initialized
F.961
Checksum from calibration
values etc.
• New EPROM version with different EEPROM structure
• Controller not yet initialized
F.962
Converter parameters not
plausible
• New EPROM version
• Controller not yet initialized
F.963
Ramp parameters not
plausible
• New EPROM version
• Controller not yet initialized
F.964
Program version /
manufacturer code
• New EPROM version
• Controller not yet initialized
F.970
Plausibility Param.block error
• New EPROM version
• Controller not yet initialized
• Some parameter is implausible