Position Adjust Parameter Values [default] Comment
01 Time activ. lock releases 01-99” [03] Relay activation of lock releases from home or access
control.
02 Time activ. exit button 00-99” [06] Relay activation of lock releases from exit button
(terminals Bs y -)
03 Panel type 0: Sub-Block Conguration of panel type
[1]: Block
2: General Entrance
04 Block Nº 00-99 [00] Block number belonging to the panel
05 Sub-Block Nº 00-99 [00] Sub-block number belonging to the panel
06 Panel Nº 0-9 [0] Panel number
07 Door sensor time 000-250 Maximum time that the door is allowed to remain
[000] inactive open once activated
08 Opening code 0000-9999 Opening code from the keyboard. The means of
[0000] inactive entering the code: A + XXXX (4 digits)
09 Programming code 0000-9999 Code to access programming
[4444]
10 MASTER panel [0]: No / 1: Yes Activation of panel as master to programme home
terminals
11 Caretaker Mode [0]: No Reset Reset to night mode by entering “1” in this position
1: Reset
12 Monitor Volume 0-9 [5] Adjust the volume of the panel monitor
13 RESET settings [0]: No Reset Return to default settings by entering a “1”
1: Reset in this position
14 Camera focus 0-9 [9] The selection of different values 0-9, represent
each of the video screens to capture.
15 Call digits for general 4 ó 6 [6] Choice of number of digits to call from
entry General Entry
16 Automatic hang-up [0]: deactivated When activated after opening the door during a
1: activated conversation, it cuts off the conversation after 5 seconds
- If you press the A key before entering the fourth digit of the opening code, the operation is
cancelled. An error tone (beep-bop) indicates that the access code has been cancelled.
- The open-door relay activation time is the same as when opening from the home.
Conguring the Direct Panel.
The outdoor panel´s parameters can be programmed on the keypad.
For this you must enter in conguration mode via a programming access code after pressing ‘A’.
Programming Access code: A + 4444 (default code).
If the code is correct, a conrmation tone sounds (beep-beep).
The parameters that can be congured are: