Festo CPX-CMAX-C1-1 2019-02a English
8
Type CPX-CMAX-C1-1
Operating voltage/load voltage
The following special features apply:
– load voltage supply range for valves
(V
VAL
)
See CPX system manual
P.BE-CPX-SYS-...
20 … 30 V
Current consumption CMAX
– from operating voltage supply for
electronics/sensors (V
EL/SEN
)
– from load voltage supply for valves
(V
VAL
)
Typ. 200 mA at 24 V
max. 300 mA
Typ. 1 … 2 A at 24 V
max. 2.5 A
Electrical isolation
– between the operating voltage
supply for the electronics/sensors
(V
EL/SEN
) and the load voltage
supply for the valves (V
VAL
)
None
Power failure bridging time 10 ms (for systems with the
DGCI, a power dropout
> 1 ms causes an error)
Axis string
Number of axis strings/Number of axes
Max. total length (all cables)
Type of axis connection
1 / 1
30 m
Socket M9, 5-pin