Go to fetco.com for the latest versions of all information Page 6 P167 March 2018
.
RECIPE Location map
Viewing and changing settings for the brew
recipes is from the “A” screens with the controls
in PROGRAMMING.
The uppermost button positions are permanent
and will not display programming step A_0.
The table above shows in position A20 that a
button position can be made active or inactive.
Position A1 does not display this step
DISPLAY
DISPLAY
STOP
BATCH A1
(permanent)
BATCH A4
(permanent)
BATCH A2
BATCH A5
BATCH A3
BATCH A6
Menu Features: Batch Parameters
The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION Program Items
Programming Range
Increments Notes
A11 Batch Volume
0.50 to 2.00 gal
1.90 to 7.60L
Unit software is in liters;
converts to gallon
A12
Brew Time
4:00 minutes 2:00 – 12:00 0.30
Default total brew time is
5:30 minutes
A13 Prewet Perc. 0% 0.00 – 15.0% 1%
Percentage of total brew
volume
A14
Prewet Delay
(Pause after prewet
completes)
0% [1:00 Min] [0:10 – 5:00] 1:00 min
prewetting and start of
brew cycle.
This feature appears
A16 Drip Delay 1:30 mm:ss 0:30 – 6:00 Min.
remain in place during final
drip-out
Drip delay remains “ON” for
1:30 minutes if STOP is
A20
A20 YES -
YES
(Active)
Middle and Bottom
batches A2,3,5,6
Batch on
or off
individually enabled,
A21 Batch Volume
0.50 to 2.00 gal
1.90 to 7.60L
Unit software is in liters;
converts to gallon
A22
4:00 minutes 2:00 – 12:00 0.30
Default total brew time is
5:30 minutes
A23 Prewet Perc. 0% 0.00 – 15.0% 1%
Percentage of total brew
volume
A24
Prewet Delay
(Pause after prewet
completes)
0% [1:00 Min] [0:10 – 5:00] 1:00 min
prewetting and start of
brew cycle.
This feature appears
A26 Drip Delay 1:30 mm:ss 0:30 – 6:00 Min.
remain in place during final
drip-out
Drip delay remains “ON” for
1:30 minutes if STOP is
CBS-1151V+Topmost Batch cannot be disabled. CBS-1152V+Topmost Batch LEFT & RIGHT cannot be disabled.
Middle and bottom batches may be disabled for single and twin brewer (CBS-1151 XV+ and CBS-1152 XV+)
† DRIP DELAY will not activate when STOP is pressed within 5 seconds of starting a brew time
CBS-1151 V+