PROGRAM Programming Items Factory set Default Programming Range Notes
Batch 1 LEFT*
Batch Summary
Display Summary
Batch Name
Regular 1(-16)
Choose from list:
Regular1
(Regular 1-16)
-OR- Write: any name
Models CBS-2130,
CBS-2140, CBS-2150-
Batch Volume
3liters to 2:00 gal
[ 0.50-2.00]
3L -1.5 gal
|_________
[]________|
0.50 2.00
Screen will display in
range and units selected
CBS-2152XTS
2 Gallon Æ
Batch Volume
2.00 gal
[ 0.50-2.25]
2.5 gal
|_____________
[]____|
0.50 2.25
For CBS-2152-2 Gallon
equipment
Brew Time
4:00 mm:ss
[ 2:00-10.00]
4:00 mm:ss
|_____
[]___________|
2:00 10:00
Nr Of Pulses
8
8
|_____
[]___________|
1 30
Prewet Perc.
0%
0 %
|_
[]_______________|
0 15
Pause after prewet
completes
Prewet Delay.
0%
0:00 mm:ss
|_
[]_______________|
0:00 1:00
This feture appears
ONLY if Prewet >0:00
Bypass Perc.
0%
0 %
|_
[]_______________|
0 40
Drip Delay
1:30 mm:ss
1:30 mm:ss
|_____
[]___________|
0:30 5:00
Default is 1 ½ minute.
Brew basket remains
locked during drip-out
Batch 2 Left**
**Batch 2-4—Right and Batch2-4—Left may be individually selected-or-entirely deleted
Batch ON/OFF
ON
ON
|_________
[]________|
ON OFF
Batch Summary
Display Summary
Batch Name
Regular 1
Regular 1-16;Write own name
Models CBS-2130,
CBS-2140, CBS-2150-
Batch Volume
3liters to 2:00 gal
[ 0.50-2.00]
3L -1.5 gal
|_________
[]________|
0.50 2.00
Screen will display in
range and units selected
CBS-2152XTS
2 Gallon Æ
Batch Volume
2.00 gal
[ 0.50-2.25]
2.5 gal
|_____________
[]____|
0.50 2.25
For CBS-2152-2 Gallon
equipment
Brew Time
4:00 mm:ss
[ 2:00-10.00]
4:00 mm:ss
|_____
[]___________|
2:00 10:00
Brew time is adutable
Nr Of Pulses
8
8
|_____
[]___________|
1 30
Prewet Perc.
0%
0 %
|_
[]_______________|
0 15
Pause after prewet
completes
Prewet Delay.
0%
0:00 mm:ss
|_
[]_______________|
0:00 1:00
This feture appears
ONLY if Prewet >0:00
Bypass Perc.
0%
0 %
|_
[]_______________|
0 40
Drip Delay
1:30 mm:ss
1:30 mm:ss
|_____
[]_________|
0:
30 5:00
Default is 1 ½ minute.
Brew basket remains
locked during drip-out
Batch 3 Left **
(See Batch 2-Left)
Batch 4 Left **
(See Batch 2-Left)
Batch 1 Right *
(See Batch 1-Left)
Batch 2 Right **
(See Batch 2-Left)
Batch 3 Right **
(See Batch 2-Left)
Batch 4 Right **
(See Batch 2-Left)
Batch Copy
Copy From Batch L1 L1-L4;R1-R4
Copy To Batch L1 L1-L4;R1-R4
Copy?
L1ÆL2?
(example)
NO
|_______________
[]__|
YES NO
*Batch 1 cannot be disabled. (CBS-2101XTS)
*Batch 1&4 cannot be disabled. (CBS-2102XTS); **Batch can be disabled, and removed from display
Batch 1 Right
Batch Name Regular 1
Batch Volume 3.00 Liter
Brew Time 4 :00
Number of Pulses 8
Prewet Percent 0 %
Prewet Delay 0:00
Drip Delay 1:30