13/68
GB
PRELIMINARY MACHINE INFORMATION 2
1
2
Using a forklift truck take the compressor as near as possible to the place where it is to be installed then
carefully remove the protective packing without damaging it, following the instructions below:
• Remove the securing screws and open cage 1.
• Take the protective cardboard 2 off.
Note! The compressor can be left on the packing pallet to make it easier to move.
Carefully ensure that the contents correspond with all written in the consignment documents. Dispose of
the packing in compliance with current standards in force in the country of installation.
Note! The machine must be unpacked by qualified personnel using appropriate tools and
equipment.
3.3 Storing the packed and unpacked compressor
For the whole time that the compressor is not used before unpacking it, store it in a dry place at a temperature
between +5°C and + 45°C and sheltered away from weather.
For the whole time that the compressor is not used after unpacking it, while waiting to start it up or due to
production stoppages, place sheets over it to protect it from dust, which may settle on the components.
The oil is to be replaced and the operational efficiency of the compressor is to be checked if it is not used
for long periods.