5
Main technical features Elektra 6.. - Elektra 12.. - Elektra 18..
Elektra.6 N HE 6 kW maximum electrical output
Single-phase electrical supply 230 V - 50 Hz.
Weight : 39
kg.
El
ectrical / heat power available at heating: 6 kW obtained by n°.1 resistance
group (n°.1 3x2 kW).
Maximum head available at the pump 5 m H
2
O
E
xpansion vessel capacity of 8 lt.
Safety valve of heating circuit: 3 bar.
Maximum heating operating pressure: 2.5 bar.
Minimum operating pressure in the heating circuit: 0.6 bar.
Maximum limit of thermal safety heating circuit - boiler body: 100 °C.
Elektra.12 N
HE 12 kW maximum electrical output
Single-phase electrical supply 230 V - 50 Hz.
Weight : 40
kg.
El
ectrical / heat power available at heating: 12 kW obtained by n°.2 resistance
groups (n°.2 3x2 kW).
Maximum head available to the pump 5 m H
2
O
E
xpansion vessel capacity of 10 lt.
Safety valve of heating circuit: 3 bar.
Maximum heating operating pressure: 2.5 bar.
Minimum operating pressure in the heating circuit: 0.6 bar.
Maximum limit of thermal safety heating circuit - boiler body: 100 °C.
Elektra.18 N
HE 1
8 kW maximum electrical output
Single-phase electrical supply 230 V - 50 Hz.
Weight : 41
kg.
El
ectrical / heat power available at heating: 18 kW obtained by n°.3 resistance
groups (n°.3 3x2 kW).
Maximum head available at the pump 5 m H
2
O
E
xpansion vessel capacity of 10 lt.
Safety valve of heating circuit: 3 bar.
Maximum heating operating pressure: 2.5 bar.
Minimum operating pressure in the heating circuit: 0.6 bar.
Maximum limit of thermal safety heating circuit - boiler body: 100 °C.