6
Display
General
switch
hydrometer
Main technical features Elektra 24..
E
l
e
ktra.24 N HE
2
4 kW maximum electrical output
Single-phase electrical supply 230 V - 50 Hz.
Weight : 42
kg.
E
l
ectrical / heat power available at heating: 24 kW obtained by n°.4 resistance
groups (n°.4 3x2 kW).
Maximum head available to the pump 6 m
H
2
O
.
Expansion vessel capacity of 10 lt.
Safety valve of heating circuit: 3 bar.
Maximum heating operating pressure: 2.5 bar.
Minimum operating pressure in the heating circuit: 0.6 bar.
Maximum limit of thermal safety heating circuit - boiler body: 100 °C.
Switching-on the boiler
C
O
NTROL PANEL
The control panel is composed of : display, function selection keys, general
switch and the hydrometer it is placed in the lower left corner
in front of the unit (see image above).