14
ADVANCED PARAMETERS
12. Power reporting interval
This parameter denes the time interval of sending at most 5 stand-
ard power reports when the power changes by the value set in pa-
rameter 11. The higher the value of parameter 12, the fewer reports
the device will send.
Available settings: 5-600 (in seconds)
Default setting: 30 (30s) Parameter size: 2 [bytes]
13. Energy reporting threshold
This parameter species the minimum change in energy consump-
tion (in relation to the previously reported), that will result in sending
a new report.
Available settings: 0 - energy reports inactive
1-500 (0.01-5kWh, step 0.01kWh) - threshold
Default setting:
10 (0.1kWh)
Parameter size: 2 [bytes]
14. Power and energy periodic reports
This parameter denes time period between independent reports
sent when changes in power load have not been recorded or if chang-
es are insignicant. By default reports are sent every hour.
Available settings: 0 - periodic reports inactive
5-32400 (in seconds)
Default setting: 3600 (1h) Parameter size: 2 [bytes]
15. Measuring energy consumed by the Wall Plug itself
This parameter determines whether power metering should include
the amount of power consumed by the Wall Plug itself. Results are
being added to the value of power consumed by controlled device.
Available settings: 0 - function inactive
1 - function activated
Default setting: 0 Parameter size: 1 [byte]
„ON/OFF” ASSOCIATION GROUPS
20. Control of „On/O (Button)” association group (2) devices
Controlling devices with the B-Button. This parameter is inactive in
“Always On” mode (parameter 1).
Control as the Wall Plug:
• switching the Wall Plug on – switch the devices on (parameter 24)
• switching the Wall Plug o – switch the devices o (parameter 24)
Control opposite to the Wall Plug:
• switching the Wall Plug on – switch the devices o
• switching the Wall Plug o – switch the devices on
NOTE
By default the Wall
Plug sends up to 5 re-
ports each 30 seconds,
provided the power
load changes by 15%.
i