15
ADVANCED PARAMETERS
Available settings: 0 - control as the Wall Plug
1 - control opposite to the Wall Plug
Default setting: 0 Parameter size: 1 [byte]
21. DOWN value - „On/O (Power)” association group (3)
Lower power threshold, used in parameter 23. DOWN value cannot
be higher than a value specied in parameter 22.
Available settings: 0-24900 (0.0-2490.0W, step 0.1W)
Default setting: 300 (30W) Parameter size: 2 [bytes]
22. UP value - „On/O (Power)” association group (3)
Upper power threshold, used in parameter 23. UP value cannot be
lower than a value specied in parameter 21.
Available settings: 100-25000 (10.0-2500.0W, step 0.1W)
Default setting: 500 (50W) Parameter size: 2 [bytes]
23. The response after exceeding dened power values
This parameter denes the way that 3rd association group devices are
controlled. Depends on the actual measured power (as parameters 21
and 22 settings).
Available settings:
1 - turn the associated devices ON, once the
power drops below DOWN value (parameter 21)
2 - turn the associated devices OFF, once the
power drops below DOWN value (parameter 21)
3 - turn the associated devices ON, once the
power rises above UP value (parameter 22)
4 - turn the associated devices OFF, once the
power rises above UP value (parameter 22)
5 - combination of 1 and 4.
Turn the associated devices ON, once the pow-
er drops below DOWN value (parameter 21).
Turn the associated devices OFF, once the pow-
er rises above UP value (parameter 22).
6 - combination of 2 and 3.
Turn the associated devices OFF, once the pow-
er drops below DOWN value (parameter 21).
Turn the associated devices ON, once the pow-
er rises above UP value (parameter 22).
Default setting: 6 Parameter size: 1 [byte]