15
ADVANCED PARAMETERS
Available settings: 0 - control as the Wall Plug
1 - control opposite to the Wall Plug
Default setting: 0 Parameter size: 1 [byte]
21. DOWN value - „On/O (Power)” association group (3)
Lower power threshold, used in parameter 23. DOWN value cannot
be higher than a value specied in parameter 22.
Available settings: 0-24900 (0.0-2490.0W, step 0.1W)
Default setting: 300 (30W) Parameter size: 2 [bytes]
22. UP value - „On/O (Power)” association group (3)
Upper power threshold, used in parameter 23. UP value cannot be
lower than a value specied in parameter 21.
Available settings: 100-25000 (10.0-2500.0W, step 0.1W)
Default setting: 500 (50W) Parameter size: 2 [bytes]
23. The response after exceeding dened power values
This parameter denes the way that 3rd association group devices are
controlled. Depends on the actual measured power (as parameters 21
and 22 settings).
Available settings:
1 - turn the associated devices ON, once the
power drops below DOWN value (parameter 21)
2 - turn the associated devices OFF, once the
power drops below DOWN value (parameter 21)
3 - turn the associated devices ON, once the
power rises above UP value (parameter 22)
4 - turn the associated devices OFF, once the
power rises above UP value (parameter 22)
5 - combination of 1 and 4.
Turn the associated devices ON, once the pow-
er drops below DOWN value (parameter 21).
Turn the associated devices OFF, once the pow-
er rises above UP value (parameter 22).
6 - combination of 2 and 3.
Turn the associated devices OFF, once the pow-
er drops below DOWN value (parameter 21).
Turn the associated devices ON, once the pow-
er rises above UP value (parameter 22).
Default setting: 6 Parameter size: 1 [byte]