40. Power load for violet colour
This parameter determines maximum active power value, which when
exceeded, causes the LED ring ash violet. Function is active only when
parameter 41 is set to 1 or 2.
Available settings: 1000-30000 (100.0-3000.0W, step 0.1W)
Default setting:
25000 (2500W)
Parameter size: 2 [bytes]
41. LED ring colour when controlled device is on
When set to 1 or 2, LED ring colour will change depending on active
power and parameter 40. Other colours are set permanently and do
not depend on power consumption.
Available settings: 0 - illumination turned o completely
1 - colour changes continuously depending on
active power
2 - colour changes in steps depending on ac-
tive power
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting: 1 Parameter size: 1 [byte]
42. LED ring colour when controlled device is o
This parameter denes the illumination colour after turning o.
Available settings: 0 - illumination turned o completely
1 - LED ring is illuminated with a colour corre-
sponding to the last measured power, before
the controlled device was turned o
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting: 0 Parameter size: 1 [byte]
43. LED ring colour at the Z-Wave network alarm detection
This parameter denes the illumination colour in case of Z-Wave alarm.
Available settings: 0 - illumination turned o completely
1 - no change in colour. LED ring colour is de-
termined by settings of parameters 41 or 42
2 - LED ring ashes red/blue/white
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting: 2 Parameter size: 1 [byte]