FIFOTRACK Q3 COMMAND LIST
17
B35 – Setting Tilt Detection
B35,<enable>,<angle>,<pre-alarm-t>,<alarm-t>,<option>,<reset-angle>
01 enable: 0~Disable tilt detection (default); 1~Enable
02 angle: Angle of change to trigger “Tilt” alarm, unit degree, range [0
o
,90
o
], default 30
o
03 pre-alarm-t: pre-alarm duration, unit second, default 30s, range [0,1000]. When tilt
detected, tracker starts voice displaying to remind user
04 alarm-t: Alarm trigger delay, unit second, default 30s. After tilt detected, tracker do
nothing but pre-alarm, and sends GPRS/SMS alarm package when alarm-t expired
05 option: Optional function for “Tilt” alarm
option==1: reset-on-motion, tracker stops pre-alarm and alarm trigger delay
when shaking
option==2: reset-on-angle, tracker stops pre-alarm and alarm trigger delay when
angle change less than reset-angle
option==3 (default): tracker stops pre-alarm and alarm trigger delay when
shaking or angle change less than reset-angle
06 reset-angle: Angle of change to stop pre-alarm and alarm trigger delay, valid when
option==2 or option==3, unit degree, default 15
o
, range [0,angle]
07 “Tilt” alarm code 25. Refer to Appendix-A for more detail
B35,<err_code>
01 err_code: procession error code.
OK – Succeed.
UNSUPPORT – Command not supported.
FAILED – Procession failed.
B35,1,30,30,20,3
01 Enable tilt detection, when angle change large than 30
o
, tracker starts pre-alarm
(voice displaying) for 30s, and delay 20s to send out “Tilt” alarm (GPRS/SMS/Call)
02 Enable reset-on-motion and reset-on-angle, during the pre-alarm period, angle
changes less than reset-angle, shaking/walking/pressing SOS button will cancel
pre-alarm and alarm trigger delay
B36 – Setting Fall Down Detection
B36,<enable>,<pre-alarm-t>,<alarm-t>,<rst-on-motion>,<accl-level>
01 enable: 0~Disable fall down detection (default); 1~Enable
02 pre-alarm-t: pre-alarm duration, unit second, default 30s, range [0,1000]. When fall
down detected, tracker starts voice displaying to remind user
03 alarm-t: Alarm trigger delay, unit second. After fall down detected, tracker does
nothing but pre-alarm, and sends GPRS/SMS alarm package when alarm-t expired
04 rst-on-motion: reset-on-motion. Shake to cancel pre-alarm and alarm trigger delay;