FIFOTRACK Q3 COMMAND LIST
26
01 cmd-code: The same as sending command.
02 cmd-para: Retrieved parameter string, the same format as setting command
described in the above chapters.
Example
Refer to chapters above.
Retrieve
UNSUPPORT
C06 Retrieve Basic Information of Tracker
Source
GPRS/COM/SMS
Description
C06
01 Retrieve basic information of tracker in batch
02 The command is commonly used for GPRS linkage lost debug
Reply
C06,<GID>,<ip>:<port>,<TCP/UDP>;APN:<apn>,<apn_user>,<apn_pwd>;BAT:<bat_v>;B0
3:<base_int>,<stop_int>;<Moving/STOP>;B71:<mode>;Cache:<cache-num>
01 GID: Tracker ID for GPRS data, default IMEI
02 ip, port: Server setting in tracker
03 TCP/UDP: Transport protocol setting, string, value TCP or UDP
04 apn, apn_user, apn_pwd: APN setting in tracker, which can be set using B01 command
05 bat_v: Voltage of internal battery, unit V
06 base_int, stop_int: GPRS uploading interval, which is the same as B03 setting
07 Moving/STOP: Current motion status, string, value Moving or STOP
08 mode: WIFI/GPS positioning mode, refer to B71 command for detail
09 cache-num: Saved GPRS blind data num, which Is not sent, and will be sent when
GPRS connected
Example
Command: C06
Reply:
C06,863921032078944,173.212.241.52:10502,TCP;APN:CMNET,,;BAT:3.93V;B03:30,600;S
top;B71:0;Cache:0
Retrieve
UNSUPPORT
S09 Setting GPRS Heartbeat Interval
Source
GPRS/COM/SMS
Description
S09,<moving-interval>,<stop-interval>
01 Heartbeat package is independent from normal GPRS position one
02 moving-interval: Heartbeat interval for moving status, unit s, default 0s
03 stop interval: Heartbeat interval for stop status, unit s, default 0s
04 When moving-interval==0 or stop-interval==0, heartbeat disabled for corresponding
status
05 When stop-interval field empty, stop-interval is set to the same value as
moving-interval
03 Heartbeat data will not be saved to blind buffer; When new heartbeat package
generated, old and unsent one will be discarded

Table of Contents

Other manuals for FIFOTRACK Q3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FIFOTRACK Q3 and is the answer not in the manual?

FIFOTRACK Q3 Specifications

General IconGeneral
BrandFIFOTRACK
ModelQ3
CategoryGPS
LanguageEnglish

Related product manuals