System 35 flexible liner
suitable for condensing
applications
System 35
adaptor
45˚ bend
500mm
adjustable length
45˚ bend
500mm
length
Boiler adaptor
System 35
clamp plate
Condensing
birdguard
Condensing
Birdguard
System 35
clamp plate
System 35 flexible liner
suitable for condensing
applications
System 35
adaptor
500mm
adjustable length
Boiler adaptor
Condensing
boiler
Condensing
boiler
Boiler
C26
C35
C44
C58
C73
Diameter
80mm
100mm
100mm
125mm
150mm
FLUE SIZE
NOTE:
All brick chimney constructions must comply with current building regulations and
BS5410 Part 1: 2014. Insulated factory made chimneys should comply with BS 4543.
Single wall stainless flue
suitable for condensing
boilers. Available in
stainless steel finish or
white finish.
CONDENSING BOILER CHIMNEY INSTALLATION
6
24
6.6 INSTALLATION - VENTILATION & COMBUSTION AIR REQUIREMENTS
INSTALLATION INSTRUCTIONS SUPPLIED WITH ALL FLUE KITS