22
The Status
The Threshold
The Zone
There is also an icon to delete the Event log.
Utilities
The following functions are located on the Utilities screen.
Table 11: Icons in the Utilities screen
Checking Battery calculations. See paragraph
Battery calculation
Using a USB stick to load the firmware, voice
messages, panel programming, and then
download the customer data.
Loading the label of the first eight zones that
should be printed and inserted in the
transparent window of the user interface. See
“Description of parts”.
Printing a PDF file that contains descriptions of
the first eight zones. You cannot resize the front
label as it is predetermined. See Figure 13.
Importing the type of wiring from a database for
use in various loop connections. These types of
wires are used in the Loop wire calculation (see
same paragraph).
Exports the battery calculation into a CSV file
that Excel or a similar application can open.
Note: By selecting Override, it is possible to adjust the
panel ID for export and import. If the option Any panel
[XXXX] is implemented, you can utilise this configuration in
any panel (for example, to load the same voice messages
in several panels).
Note: In the printer driver, set the Page resizing option to
None.
Note: You can move the database from one system to
another. The console searches for the wire database on
start up. If you cannot access a moved database, close the
software and restart.
Battery calculation
The Battery calculation window allows you to see the
following (see Figure 14):
The FC503 loads: Loop 1, Loop 2, Loop 3 device
loads.
The FC506 loads: Loop 1, Loop 2, Loop 3, Loop 4,
Loop 5, Loop 6 device loads in the condition of
Normal load and Alarm loads (percentage of
devices in Alarm status), when the Mains fails.
Below this window, in the option Others load, you
can insert Loads on auxiliary terminals if required.
Automatically, the Total load, the Battery needed
and the Battery recharge time appears. Set the
Standby hours, Alarm minutes values and the
calculation will occur.
Battery calculation parameters
Stand-by hours (from 1 to 144h)
Alarm minutes (from 1 to 240m)
Battery type
This is the battery (Ah) arising from calculation.
Battery calculation constraints
Lock standby hours
Lock battery type
Lock standby hours
Battery type value (Ah) will be calculated, fixed Standby
hours, Alarm minutes.
Lock battery type
Standby hours value will be calculated, fixed Battery type
(Ah), Alarm minutes.
Note: The software calculation is a rough calculation and
cannot substitute the installer or qualified person’s
calculation.
Figure 13: Page to print the zones label
Commented [RH5]: Please clarify where this paragraph is
so I can create a hyperlink
Commented [RH6]: Again, could you clarify the
paragraph to refer to