Type 24
Silent Burglary
Usually assigned to all sensors or contacts on exterior doors and windows where
bells and/or sirens are NOT desired.
Provides an instant alarm, with NO audible indication at any keypad or external
sounder, if the zone is faulted when the system is armed in the Away, Stay,
Instant, or Maximum modes.
A report is sent to the central station.
Type 77
Keyswitch
Assign to zone wired to a keyswitch.
Do not use devices assigned as input type BR with this zone type.
Type 81
AAV Monitor Zone
Assign to zone connected to AAV module.
Monitors 2-way voice sessions as follows:
- When the zone is faulted, all alarm sounding and dialer reporting stops, except
for fire alarms, which immediately terminate the voice session and cause
a fire report to be sent.
- When the zone is restored (session ended), sounding resumes (if bell timeout
has not expired) and reports that were stopped are sent.
Types 90-93
Configurable
Allows for various custom responses. Options include response to entry/exit delays,
response opens/shorts, types of alarm/trouble sounding, dial delay, and unique
Contact ID report codes. Types 92 and 93 can only be programmed via downloader.
UL installations: Zone Types 90 -93 may not be used as fire or burglar alarm zones
on fire or UL burglar alarm installations.
*
The system can still be armed when these zone types are in a faulted condition.
NOTE:
All of the zone types described are available for the wireless portion of the system, if used.
Mechanics of Programming
To program the system from a keypad:
You must use a 2-line Alpha display keypad.
Both partitions must be disarmed.
Data Field Programming Procedures
Task Procedure
Entering Program Mode
A) Press both [
] and [#] at the same time within 50 seconds after power is applied
to the control,
OR
B) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0 (long beep indicates one
of the partitions is armed and system cannot enter program mode).
(method B is disabled if you exit the program mode using
98)
Go to a Data Field
Press [
] + [Field Number] (for example,
21).
A display of
EE
or
Entry Error
means you have entered a nonexistent field.
Simply re-enter [
] plus a valid field number.
Entering Data
When the desired field number appears, simply enter the digits required. The
keypad beeps three times after the last digit is entered and automatically displays
the next data field in sequence.
If entering less than the maximum digits available (e.g., phone number field),
enter the desired digits, then press [
] to end the entry.
Review a Data Field
Press [#] + [Field Number].
That fields data is displayed, but no changes can be made.
Deleting an Entry
Press [
] + [Field No.] + [
]
(applies only to phone number, account number, and
pager character fields).
3-5

Table of Contents

Other manuals for First Alert FA168CPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA168CPS and is the answer not in the manual?

First Alert FA168CPS Specifications

General IconGeneral
BrandFirst Alert
ModelFA168CPS
CategorySecurity System
LanguageEnglish

Related product manuals