FIELD
TITLE and DATA ENTRIES
EXPLANATION
*164
Pager 2 Characters
Enter up to 16 characters
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
164
.
*165
Pager 2 Report Options
see pager 1 reports, field *162 for entries,
except use zone list 10.
Enter the types of reports to be sent to pager 2 for each partition.
*166
Pager 3 Phone No.
Enter up to 20 digits
FA168CPS.
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
166
.
*167
Pager 3 Characters
Enter up to 16 characters
FA168CPS.
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
167
.
*168
Pager 3 Report Options
see pager 1 reports, field *162 for entries,
except use zone list 11.
FA168CPS.
Enter the types of reports to be sent to pager 3 for each partition.
*169
Pager 4 Phone No.
Enter up to 20 digits
FA168CPS.
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
169
.
*170
Pager 4 Characters
Enter up to 16 characters
FA168CPS.
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
170
.
*171
Pager 4 Report Options
see pager 1 reports, field *162 for entries,
except use zone list 12.
FA168CPS.
Enter the types of reports to be sent to pager 4 for each partition.
*172
Pager Delay Option for Alarms
0 = none 2 = 2 minutes
1 = 1 minute 3 = 3 minutes
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
it received, before the dialer attempts to dial the pager.
This delay is for ALL pagers in the system.
Miscellaneous System Fields
*174
Clean Me Option
0 = disable
1 = enable
This is a maintenance feature for ESL 2-wire smoke detectors
on Zone 1. If used, this option limits the number of smoke detectors to
a maximum of 10, rather than 16. To enable the clean me feature, a
time response setting of 3 (1.2 seconds) must be entered in
56 Zone
Programming for zone 1.
*177
Device Duration 1, 2
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min
1 = 30 secs 7 = 3 min #+13 = 10 min
2 = 45 secs 8 = 4 min #+14 = 12 min
3 = 60 secs 9 = 5 min #+15 = 15 min
4 = 90 secs #+10 = 6 min
5 = 2 min #+11 = 7 min
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in
80 Output Function
Programming.
*181
50/60 Hz AC Operation
0 = 60 Hz
1 = 50 Hz
Select the type of AC power applied to the control.
This option is used for Real-Time Clock synchronization.