FO2 - On lock and Unlock only:
this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start:
this option will provide a horn output pulse (based on the
option selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
FO4 - On double lock and Start:
this option is designed to simulate a factory keyless entry
system by providing a horn output pulse (based on the option selection of feature 3-02) each time
the lock command is sent a second time within 8 seconds of the first. It will also provide a horn
output pulse with remote start command and remote start confirmation.
3-10 Valet Mode:
This feature will change the enter/exit valet mode procedure based on the option
selected.
FO1 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk) while Ignition is on:
This option allows the user to enter valet mode using either method described.
Note: the user
may exit valet mode with their Firstech remote (please check users guide for each remote
for valet mode exit procedure), or with the key to ignition or “on” position and press the
foot brake 10 times within 10 seconds.
FO2 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk): This option allows the
user to enter valet mode using either method described. Note: the user may exit valet mode with
their Firstech remote (please check users guide for each remote for valet mode exit
procedure), or with the key to ignition or “on” position and press the foot brake 10 times
within 10 seconds.
3-13 Defrost Output Temp Control:
This feature will determine the temperature at which the CM-900
will provide an output on any POC programmed with setting 17 or 21 (defrost and defrost 2).
FO1 - Standard:
(Default) this option will provide an output (length of output based on feature 3-13
option settings) on any POC programmed with setting 17 (defrost) or 21 (defrost 2) every time with
remote start confirmation.
FO2 - 32°F:
(FT-TEMP SENSOR required) this option will provide an output on any POC
programmed with setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will
happen if the temp reading is at or below 32°F. (Length of output based on feature 3-13 option
settings)
FO3 - 42°F: (FT-TEMP SENSOR required) this option will provide an output on any POC
programmed with setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will
happen if the temp reading is at or below 42°F. (Length of output based on feature 3-13 option
settings)
3-14
Defrost Output Timing:
This feature controls the output timing of POC setting 17, defrost.
Note:
POC setting 21 defrost 2 is has a fixed pulsed output and is NOT affected by this feature.
FO1 - 500mS Pulse:
This option will provide a 500 Millisecond pulsed output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option setting.
FO2 - 3 minute latched:
This option will provide a 3 minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option setting. (This
would be good for any rear view mirror defrost that may need a short latched output time.)
FO3 - 7 minute latched:
This option will provide a 7 minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option settings. (This