EasyManua.ls Logo

Firstech CM-900 - Page 24

Firstech CM-900
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
would be good for many front, rear, or rear view mirror defrost functions that may need a longer
latched output time.)
FO4 - Latched for Entire Runtime: (Remote start runtime based off of feature 2-07 option setting)
This feature will provide a latched output for the entire remote start runtime on any POC
programmed with setting 17 (defrost) with timing based off of feature 3-12 option settings. Caution:
make sure not to latch rear defrost functions on for too long as it may cause damage to the heating
elements in the window.
4-01 Aux 1 Output:
This feature determines the duration of the auxiliary 1 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update
only)
(Specific time setting only available when using the OP500)
FO1 - 500mS:
This option will provide a (-) negative output for 500 milliseconds (Half second)
output on any POC programmed with setting 10 (AUX 1)
FO2 - Latched:
This option will provide a latched (-) negative output on any POC programmed
with setting 10 (AUX 1).
Note: This will stay latched until AUX 1 command is sent again to
shut it off.
FO3 - 500mS pulse + programmable timed output:
This option will provide a (-) negative output
for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 10 (AUX 1). It will
pause for 250 milliseconds then provide a timed output (based off of feature 4-01 option 4). Note:
in order to program the timed output the user must change feature 4-01 to option 4, then adjust
AU1 (AUX programmable output time) to desired time. To complete the programming steps feature
4-01 must be changed to option 3. I.e. 0.5 second pulse…pause…10 second pulse, this option can
be used to roll windows up or down on a vehicle that requires a similar action using the driver’s
door key cylinder.
FO4 - Program:
This option allow the AUX output time to be programmed for a duration between
1-99 seconds. Note: with an OP500 update there will be additional time duration between 1-15
minutes available.
4-02 Aux 2 Output:
This feature determines the duration of the auxiliary 2 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update
only) only available when using the OP500)
FO1 - 500mS:
This option will provide a (-) negative output for 500 milliseconds (0.5 seconds)
output on any POC programmed with setting 11 (AUX 2)
FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed
with setting 11 (AUX 2). Note: This latched output will reset when ignition is turned on.
FO3 - 500mS pulse + programmable timed output:
This option will provide a (-) negative output
for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 11 (AUX 2). It will
pause for 250 milliseconds then provide a timed output (based off of feature 4-02 option 4). Note:
in order to program the timed output the user must change feature 4-02 to option 4, then adjust
AU2 (AUX programmable output time) to desired time. To complete the programming steps feature
4-01 must be changed to option 3. (i.e. half second pulse…pause…10 second pulse)
This option
can be used to roll windows up or down on a vehicle that requires a similar action using the
driver’s door key cylinder.
FO4 - Program:
This option allows the AUX output time to be programmed for a duration between
1-99 seconds.
Note: The OP500 must be updated for additional time duration settings. (1-15
minutes available)

Related product manuals