would be good for many front, rear, or rear view mirror defrost functions that may need a longer
latched output time.)
FO4 - Latched for Entire Runtime: (Remote start runtime based off of feature 2-07 option setting)
This feature will provide a latched output for the entire remote start runtime on any POC
programmed with setting 17 (defrost) with timing based off of feature 3-12 option settings. Caution:
make sure not to latch rear defrost functions on for too long as it may cause damage to the heating
elements in the window.
4-01 Aux 1 Output:
This feature determines the duration of the auxiliary 1 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update
only)
(Specific time setting only available when using the OP500)
FO1 - 500mS:
This option will provide a (-) negative output for 500 milliseconds (Half second)
output on any POC programmed with setting 10 (AUX 1)
FO2 - Latched:
This option will provide a latched (-) negative output on any POC programmed
with setting 10 (AUX 1).
Note: This will stay latched until AUX 1 command is sent again to
shut it off.
FO3 - 500mS pulse + programmable timed output:
This option will provide a (-) negative output
for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 10 (AUX 1). It will
pause for 250 milliseconds then provide a timed output (based off of feature 4-01 option 4). Note:
in order to program the timed output the user must change feature 4-01 to option 4, then adjust
AU1 (AUX programmable output time) to desired time. To complete the programming steps feature
4-01 must be changed to option 3. I.e. 0.5 second pulse…pause…10 second pulse, this option can
be used to roll windows up or down on a vehicle that requires a similar action using the driver’s
door key cylinder.
FO4 - Program:
This option allow the AUX output time to be programmed for a duration between
1-99 seconds. Note: with an OP500 update there will be additional time duration between 1-15
minutes available.
4-02 Aux 2 Output:
This feature determines the duration of the auxiliary 2 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update
only) only available when using the OP500)
FO1 - 500mS:
This option will provide a (-) negative output for 500 milliseconds (0.5 seconds)
output on any POC programmed with setting 11 (AUX 2)
FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed
with setting 11 (AUX 2). Note: This latched output will reset when ignition is turned on.
FO3 - 500mS pulse + programmable timed output:
This option will provide a (-) negative output
for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 11 (AUX 2). It will
pause for 250 milliseconds then provide a timed output (based off of feature 4-02 option 4). Note:
in order to program the timed output the user must change feature 4-02 to option 4, then adjust
AU2 (AUX programmable output time) to desired time. To complete the programming steps feature
4-01 must be changed to option 3. (i.e. half second pulse…pause…10 second pulse)
This option
can be used to roll windows up or down on a vehicle that requires a similar action using the
driver’s door key cylinder.
FO4 - Program:
This option allows the AUX output time to be programmed for a duration between
1-99 seconds.
Note: The OP500 must be updated for additional time duration settings. (1-15
minutes available)