Alarm
System
www.firstechonline.com
|
www
.compustar.com
CM2500
Guide
Copyright 2022 Fi rstech , LLC. “Are you not entertained…?” Page
28
Universal Security Control Module
Install.myfirstech.com
CM2500
Master
Guide
2-03 (-)Ground while armed (GWA)(-)250mA Output: This feature controls behavior of the Blue wire
PIN 9 on CN4.
FO1 - Latched: this option will provide a constant or ”latched” output on the Blue wire once the
system is in the armed state. This can be used to control a .er interrupt relay, an LED panel, or
AUX.
FO2 - 0.5 second pulse: This option will provide a ½ second pulsed output on the Blue wire
when the system is armed
FO3 - 20 second pulse: This option will provide a 20 second pulsed output on the Blue wire
when the system is armed
FO4 - AUX 4 PROGRAM: This option will allow the Blue wire to be used as AUX 4 (triggered
with arm command) and set to a specific timed output using an OP500 programmer. SEE
Special options group for timing options 1-100 seconds.
2-04 Dome Light Supervision output: This feature will control the output which is designed to power
the interior lighting of a vehicle. The options will determine when the output is triggered and
how long it can stay on.
FO1- Arm & 45 seconds after disarm: This option enables the Dome light supervision output
to activate with the arm command, and it will activate with disarm command staying on for up to
45 seconds or ignition on
FO2 - Arm: This option enables the Dome light supervision output to activate with the arm
command.
FO3 - 45 seconds: This option enables the Dome light supervision output to activate with the
disarm command staying on for up to 45 seconds or ignition on
FO4 - OFF: This option will disable the dome light supervision output.
2-05 Unlock / Disarm with Trunk Release:
FO1 - Unlock, Factory Alarm Disarm (FAD) trunk release: This option will send unlock and
FAD outputs prior to sending the Trunk release output. This applies to analog and data to data
situations.
FO2 - Factory Alarm Disarm (FAD) with trunk release: This option will send the FAD
output prior to sending the trunk release output. This applies to analog and data to data
situations.
FO3 - Trunk release only: This option will only send the trunk release output when triggered.
This applies to analog and data to data situations.
FO4 - AUX 3: This option allows the trunk release wire to be set to AUX 3 and have a
programmable timed output when using the trunk release command. See feature 2-06 option 4
and special options group for 1-100 second timing options.
2-06 Trunk Release Output Timing: This feature determines the length of output time for the (-) analog
trunk release wire.