Alarm
System
www.firstechonline.com
|
www
.compustar.com
CM2500
Guide
Copyright 2022 Fi rstech , LLC. “Are you not entertained…?” Page
31
Universal Security Control Module
Install.myfirstech.com
CM2500
Master
Guide
FO2 - Zone 1 Arm/Disarm disable input - Zone 2 instant trigger: This option allows the
impact sensor port (red) input zone 1 to be used to disable the arm/disarm commands when (-)(-
)ground is applied at the same time as an analog arm/disarm input command. This can be used to
prevent the system from being disarmed by interior door lock switches, when connected to OEM
door lock motors for use with older OEM remotes. Zone 2 can be used as an instant trigger
activation which will trigger the full alarm when (-) is applied while the system is armed.
FO3 - Standard Analog Shock: This option allows the CM2500 to communicate with the FT-
Shock analog shock sensor. This impact sensor is manually adjustable on the sensor and is
capable of reporting zone 1 and zone 2 impacts.
FO4 - DAS 2: this options enables the 4 in one DAS 2 support on the CM2500.
2-13 Sliding door control for iDatalink: (must be enabled to allow data to data sliding door control)
This feature will provide an Unlock or Factory Alarm Disarm (FAD) output when triggering the
AUX control using iDatalink Modules (Sliding Doors)
FO1 - Off: (default) This option does not provide an unlock or a FAD output when activating
AUX
output control using the iDatalink modules.
FO2 - Unlock and FAD: This option will provide unlock and a FAD output when activating
AUX
output control using iDatalink modules.
FO3 - FAD only: This option will only provide a FAD (factory alarm disarm) output when
activating
AUX output control using iDatalink modules
2-14 Soft Disarm: this feature will enable Factory Alarm Arm (FAA) and Factory Alarm Disarm (FAD)
outputs to trigger when silencing the Compustar siren when sounding with full alarm.
FO1 - Off: (Default) this will keep the standard Compustar soft disarm operation. Soft disarm feature
allows the user to silence the Compustar siren as its sounding with full alarm without fully disarming
the system which may unlock the doors and leave the vehicle unsecure.
FO2 - On: this option will provide a FAD output when the user taps the unlock/disarm once to silence
the Compustar system while it’s sounding, so it will disarm any factory alarm that may be sounding as
well. In case the FAD function unlocks the doors the CM will send the FAA, 5 seconds later to make
sure the vehicle is re-locked and secure. (This feature works well with GM, Chrysler, Dodge, Jeep,
Toyota, Lexus vehicles that may have factory security.)
FO3 - Disarm with 1 press: This option will allow the user to completely disarm the system once it
is sounding on the first unlock command. When set to this option the CM will unlock and send the
FAD commands on the first disarm/unlock press from a Firstech remote.