On the brain, how do I set the auxiliaries?
A: You must have an Option Programmer (FT-OP500-KIT) to set the auxiliaries on the CM4000, CM4200-
DX, CM4300, CM5000, CM5200, CM6000, CM6200 and CM6300. First choose two POC wires on
CN3 that you are not using. With the OP500 go into the Special Option Group 2 and set those POC’s to
Aux 1 and Aux 2. Review the “Special Option Group” programming section of this manual. On the CM6
Series control modules, Auxiliary 1 is pre programmed on CN3, Pin 19, Violet Wire.