EasyManuals Logo

Firstech CM6200 User Manual

Firstech CM6200
36 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Firstech technical support is reserved for authorized dealers only.
Monday - Friday: 888-820-3690
(8:00 am – 5:00 pm Pacific Coast Time)
Email: support@compustar.com
Web: www.compustar.com/dealersupport
Wire Diagrams
Click on the “Installogy Access Client” link found on your desktop. If you are a qualified dealer and unable
to access this site, call your sales representative or the number above.
Technical Support Contacts CM6200
On the brain, how do I set the auxiliaries?
A: You must have an Option Programmer (FT-OP500-KIT) to set the auxiliaries on the CM4000, CM4200-
DX, CM4300, CM5000, CM5200, CM6000, CM6200 and CM6300. First choose two POC wires on
CN3 that you are not using. With the OP500 go into the Special Option Group 2 and set those POC’s to
Aux 1 and Aux 2. Review the “Special Option Group” programming section of this manual. On the CM6
Series control modules, Auxiliary 1 is pre programmed on CN3, Pin 19, Violet Wire.
CM6200 Install Guide
Starter System
www.firstechonline.com | www.compustar.com
Copyright 2012 Firstech, LLC.
Page 36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Firstech CM6200 and is the answer not in the manual?

Firstech CM6200 Specifications

General IconGeneral
BrandFirstech
ModelCM6200
CategoryRemote Starter
LanguageEnglish

Related product manuals