321144
51
7.4 Key Presses
To activate any mode, certain combinations of key presses are required.
The key-presses are as follows. Key presses used by the service technician are those shown shaded.
Version 2 LCD Display
Function Key Presses Action Press Time
Dispenser Lock
Lock
On/Off Hold down for 2 seconds
Key Lock
Lock
On/Off Hold down for 4 seconds
Diagnostic Mode Menu + Up
+
On Hold down for 4 seconds
Manually Forced
Defrost
Menu + Down
+
On Hold down for 4 seconds
Sabbath Mode Lock + Menu + Down
+ +
On/Off Hold down for 4 seconds
Disable Filter Alarm Menu + Up + Lock
+ +
On/Off Hold down for 4 seconds
Show Off Mode Menu + Down + Up
+ +
On/Off Hold down for 4 seconds
Filter Reset Lock + Up
+
Reset Hold down for 4 seconds
Manually Force
Icemaker Harvest
Lock + Down + Up
+ +
Activates
once
Hold down for 4 seconds
7.5 Temperature Settings
PC Setting
0.0
O
C 0.5
O
C 1.0
O
C 1.5
O
C 2.0
O
C 3.0
O
C 4.0
O
C 5.0
O
C 6.0
O
C 7.0
O
C 8.0
O
C
32
O
F 32.9
O
F 33.8
O
F 34.7
O
F 35.6
O
F 37.4
O
F 39.2
O
F 41
O
F 42.8
O
F 44.6
O
F 46.4
O
F
Colder Warmer
FC Setting
-21.0
O
C -20.0
O
C -19.5
O
C -18.5
O
C -18.0
O
C -17.5
O
C -17.0
O
C -16.5
O
C -15.5
O
C -15
O
C-14.0
O
C
-5.8
O
F -4.0
O
F -3.1
O
F -1.3
O
F -0.4
O
F 0.5
O
F 1.4
O
F 2.3
O
F 4.1
O
F 5
O
F 6.8
O
F
Colder Warmer
Default factory settings are +3
O
C (37.4
O
F) for the provision compartment and -18
O
C (-0.4
O
F) for the freezer
compartment.
NOTE: Crowbar setting for the PC is -4
O
C (24.8
O
F) and for the FC is -26
O
C (-14.8
O
F). Temperatures shown
are average temperatures.