10.1.5 Diagnostic Modes
To enter diagnostic modes, press and hold the MENU button, then press the UP button for 4 seconds. The
PC sensor temperature will be displayed on the LCD as shown in Diagram A. The actual temperature of the
PC is shown.
NOTE 1: All temperatures shown on display are in degrees Celsius.
NOTE 2: The door alarms do not operate when the appliance is in diagnostic mode.
PC Sensor Temperature
NOTE: 4.0 shown on display, indicates the temperature of the PC sensor is 4.0
O
C (39.2
O
F).
Diagram A
PC Sensor Temperature
FC Sensor Temperature
Press the UP button once more – FC sensor temperature.
NOTE: 12.0 min shown indicates the temperature of the FC sensor is -12
O
C (10.4
O
F).
Diagram B
FC Sensor Temperature
Defrost Sensor Temperature
Press the UP button once more – Defrost sensor temperature.
NOTE: 18.0 min shown indicates the temperature of the Defrost sensor is -18
O
C (0.4
O
F).
Diagram C
Defrost Sensor Temperature