7 ELECTRONIC MODULE CONNECTION CHECK
The following is a quick test procedure to check that the electronic module is correctly wired to the
dryer and that the dryer is operating correctly
7.1 Led & Button Test
1. Press and hold the LOCK, button, and then press the DRYNESS up button so that
both buttons are pressed down at the same time.
All LEDs should be on:
2. Press the POWER
button to turn the LEDs off.
3. Press the POWER
button and check all the other buttons are working. Check that the
buzzer is sounding.
7.2 Drum Rotation & Element Check
1. Connect an amp meter or watt meter in the mains supply to the dryer.
Turn the dryer on and set the temperature to Regular, then press the START/PAUSE
button to start.
Amp meter should read approx 8.5 amps OR watt meter should read 2000 watts.
Note 1: If the dryer does not start, check the door switch adjustment (for other faults refer to
the FAULT CODES section).
Note 2:
A failure on the control module will cause a fault code to be displayed on the
Dryness LEDs. This happens approximately 12 seconds after the initial pressing of the
START/PAUSE
button and overwrites the operational display (refer to the FAULT
CODES section).
2. Press the START/PAUSE
button twice.
The dryer should stop and reverse direction.
Amp meter should again read approx 8.5 amps or the watt meter should read 2000 watts.
3. Press the START/PAUSE
button and use the TEMPERATURE down button to set
the temperature to airing.
4. Press the START/PAUSE
button the Amp meter should read approximately 0.5 amps or
the watt meter 130 watts.