POWERFLARM
FUSION USER AND
MAINTENANCE
MANUAL
Date: 2020-11-10
Version: 1.0
Page: 45 of 49
FLARM Technology Ltd
Hinterbergstrasse 15
CH-6330 Cham
Document Number:
FTD-078
6
Firmware update
Update the PowerFLARM firmware and FLARM Hub
firmware to the latest version. See Section 3.5 and
Section 9.1 for details.
7
Display update
Install the latest display firmware, if applicable. It
can be acquired from the display manufacturer.
8
Configuration
If the PowerFLARM firmware release notes indicate
that configuration settings have been added or
changed, reconfigure the device
as required. See
Section 3.4.1 and Section 5 for details.
9
Obstacle database
update
If an obstacle database is installed, update the
database to the latest version. See Section 5.2 for
details.
10
Status/Error
conditions
Power on Fusion and verify that no error occurs
during the boot sequence. If an error occurs, check
the severity and type of error (error code) to
determine the proper remedy. Error codes are
listed in Appendix B.
Verify that Fusion has GNSS reception at the latest
15 minutes after power-
on. The aircraft/device
must be outside with a clear view of the sky. The
system should indicate GPS and TX (Transmit). In
addition, RX (Receive) should be indicated if other
transmitting FLARM-
equipped aircraft are within
range.
Verify that connected displays are showing normal
indications. See the display manual for details.