Appendix B List of Error Codes
The table below lists the error codes that can be indicated and their meaning. The
hexadecimal value of the error code is shown. Some displays may instead indicate
the decimal value and/or a text description. The possible error code range is from
0 to FFF.
Error Code (Hex)
Meaning
11
Firmware expired (requires valid GNSS information, i.e.
will not be available during the first minutes after power-
on)
12
Firmware update error
21
Power (e.g. voltage below minimum)
22
UI error
23
Audio error
24
ADC error
25
SD card error
26
USB error
27
LED error
28
EEPROM error
29
General hardware error
2A
Transponder receiver Mode-C/S/ADS-B unserviceable
2B
EEPROM error
2C
GPIO error
31
GNSS communication
32
Configuration of GNSS module
33
GNSS antenna
41
RF communication
42
Another FLARM device with the same Radio ID is being
received. Alarms are suppressed for the relevant device.
43
Wrong ICAO 24-bit address or radio ID
51
Communication
61
Flash memory
71
Pressure sensor
81
Obstacle database (e.g. incorrect file type)
82
Obstacle database expired
91
Flight recorder
93
Engine-noise recording not possible
94
Range analyzer
A1
Configuration error, e.g. while reading flarmcfg.txt from
SD/USB
B1
Invalid obstacle database license (e.g. wrong serial
number)
B2
Invalid IGC feature license
B3
Invalid AUD feature license
B4
Invalid ENL feature license

Table of Contents