第 二十六 页 共 二十六
An interface will appear by clicking the cross-shaped function key.
Input the target values. 220 degrees for the extruder (maximum 230 degrees); 115
degrees for the heating platform (maximum 120 degrees). After input, the platform
will start to warm up. When the extruder temperature reaches 50 degrees, the cooling
fan will activate and the current temperature value will display to the right, as shown
below.