3 - PROGRAM LEVEL #1
LEVEL #1 - OPTION SETTINGS - INSTALLER
PROGRAMMING
This level includes the functioning parameters of the softener related to the site conditions.
Note: If the chemical pump output feature is active, first remove the flow meter harness from the meter
cover before entering any program level.
ENTERING LEVEL #1
A- Press the button for 5 seconds. The program arrow turns on and the first display viewed is
used to set the inlet water hardness.
B- The and set buttons are used to set the parameter values of different displays.
C- Passing to the next display, push the button.
Note: depending on the current programming, certain displays will not be viewed or set.
WATER HARDNESS
Not viewed in timeclock regeneration mode or when the volume override is activated.
The unit of measure used for the parameter is °tH
(1)
. The red led next to the symbol identifies this
parameter . Adjust the value with the and set buttons.
Ex.: Hardness 30 °tH
(1)
[- - - - - 30]
WATER HARDNESS AFTER THE MIXING VALVE (P)
Not viewed in timeclock regeneration mode, with the volume override activated, or in US format, or if 8
set on 1
(2)
.
Press button. The letter "P" identifies this parameter. The unit of measure is the °tH
(1)
. Adjust
the value with the and set buttons.
Ex.: Hardness after the mixing valve 6 °tH
(1)
: [P - - - - 6]
SYSTEM CAPACITY
Not viewed in timeclock regeneration mode or when the volume override is activated.
Press the button. The red led next to the symbol turns on. The unit of measure used is
the m
3
°tH(1). This display is used to set the capacity of the softener. If required, the electronics
will calculate a reserve. Adjust the value with the and set buttons.
Ex.: Capacity 1200 m
3
°tH
(1)
: [- - - -1200]
(1)
The unit of measure depends on the display format chosen. All examples above are
based on the cubic meter format. (see point 2.12).
(2)
see point 2.16