Technical data9
9.10 FLIR A310f 90°
P/N: 61201-1105
Rev.: 35207
General description
The main purpose of the housing on the FLIR A310f is to increase the environmental specification of
the standard FLIR A310 to IP66 without affecting any of the features available in the camera itself.
The built-in FLIR A310 camera offers an affordable and accurate temperature measurement solution for
anyone who needs to solve problems that need built in “smartness” such as analysis, alarm functional-
ity, and autonomous communication using standard protocols. The FLIR A310 camera also has all the
necessary features and functions to build distributed single- or multi-camera solutions utilizing standard
Ethernet hardware and software protocols.
The FLIR A310 camera also has built in support to connect to industrial control equipment such as
PLCs, and allows for sharing of analysis and alarm results and simple control using the Ethernet/IP and
Modbus TCP field bus protocols.
Key features:
Encapsulation to IP66.
Support for the EthernetIP field bus protocol (analyze, alarm, and simple camera control).
Support for the Modbus TCP field bus protocol (analyze, alarm, and simple camera control).
Built-in extensive analysis functionality.
Extensive alarm functionality, as a function of analysis and more.
On schedule: file sending (FTP) or e-mail (SMTP) of analysis results or images.
On alarms: file sending (FTP) or e-mail (SMTP) of analysis results or images.
MPEG-4 streaming.
PoE (Power over Ethernet).
Built-in web server.
General purpose I/O.
100 Mbps Ethernet (100 m cable, wireless, fiber, etc.).
Synchronization through SNTP.
Composite video output.
Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included.
Open and well-described TCP/IP protocol for control and set-up.
16-bit 320 × 240 pixel images at 7–8 Hz, radiometric.
Typical applications:
Safety with temperature alarms (multi-camera applications), fire prevention, critical vessel monitor-
ing, and power utility asset management.
Volume-oriented industrial control (multi-camera installation is possible).
Imaging and optical data
IR resolution 320 × 240 pixels
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV)
90° × 73°
Minimum focus distance 20 mm (0.79 in.)
Focal length 4 mm (0.157 in.)
Spatial resolution (IFOV)
6.3 mrad
Lens identification Automatic
F-number 1.3
Image frequency 30 Hz
Focus Automatic or manual (built in motor)
Zoom 1–8× continuous, digital, interpolating zooming on
images
Detector data
Detector type Focal plane array (FPA), uncooled
microbolometer
Spectral range
7.5–13 µm
#T559794; r. AJ/35709/35709; en-US