FLIR LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
27
Temperature
Gain Mode
Threshold Low to
High (K)
Temperature threshold in Kelvin used to
determine when an Auto switch to High gain
mode (while in Low gain mode) should occur in
TLinear mode
Population Gain
Mode Threshold
High to Low
Population threshold in percent of the Gain Mode
ROI used to determine when an Auto switch to
Low gain mode (while in High gain mode) should
occur
Population Gain
Mode Threshold
Low to High
Population threshold in percent of the Gain Mode
ROI used to determine when an Auto switch to
High gain mode (while in Low gain mode) should
occur
(startRow, startCol, endRow, endCol)
T-Linear resolution (0 = 0.1, 1 = 0.01)
Spotmeter mean value in Kelvin within ROI
Spotmeter max value in Kelvin within ROI
Spotmeter min value in Kelvin within ROI
Number of pixel in Spotmeter ROI